Jul 172015
 

Intro

It took me a while to figure out optimal configuration for the tape library with two streamers used with Bacula backup software.

Exact model of tape library in use is Quantum Scalar i40 with two LTO5 streamers. It is hooked up directly to the main NFS server (so heavy backup traffic goes via localhost only) – server that runs bacula-sd and bacula-fd services only. Bacula director runs on separate, dedicated backup server.

Currently there are around 20 other servers connected to this system as clients, with various daily Incremental, weekly Differential and monthly Full backup level jobs scheduled for execution.

Some additional info about this setup in previous post – click here. Config files below:

insta-24

 


Relevant config files from Backup server


/etc/bacula/bacula-dir.conf

Director {  
  Name = prod-backup-dir
  QueryFile = "/etc/bacula/scripts/query.sql"
  WorkingDirectory = "/var/lib/bacula"
  PidDirectory = "/var/run/bacula"
  Password = "xxxxx"
  Messages = Daemon
  DirAddress = prod-backup.domain.com
  Maximum Concurrent Jobs = 20
}
@/etc/bacula/JobDefs/JobDefs.conf
@|"sh -c 'cat /etc/bacula/Job/*'"
@|"sh -c 'cat /etc/bacula/FileSet/*'"
@|"sh -c 'cat /etc/bacula/Schedule/*'"
@|"sh -c 'cat /etc/bacula/Clients-enabled/*'"
@|"sh -c 'cat /etc/bacula/Storage/*'"
@|"sh -c 'cat /etc/bacula/Pool/*'"
Catalog {
  Name = MyCatalog
  dbaddress = prod-db.domain.com ;
  dbname = "bacula"; dbuser = "bacula"; dbpassword = "xxxxx"
}
Messages {
  Name = Standard
  mailcommand = "/usr/lib/bacula/bsmtp -h prod-mailhub.domain.com -f \"\(Bacula\) \<%r\>\" -s \"Bacula: %t %e of %c %l\" %r"
  operatorcommand = "/usr/lib/bacula/bsmtp -h prod-mailhub.domain.com  -f \"\(Bacula\) \<%r\>\" -s \"Bacula: Intervention needed for %j\" %r"
  mail = [email protected] = all, !skipped            
  operator = [email protected] = mount
  console = all, !skipped, !saved
  append = "/var/lib/bacula/log" = all, !skipped
  catalog = all
}
Messages {
  Name = Daemon
  mailcommand = "/usr/lib/bacula/bsmtp -h localhost -f \"\(Bacula\) \<%r\>\" -s \"Bacula client %c job %n exit code %e  \" %r"
  mail = [email protected] = all, !skipped            
  console = all, !skipped, !saved
  append = "/var/lib/bacula/log" = all, !skipped
}
Console {
  Name = prod-backup-mon
  Password = "xxxxxxxxxxx"
  CommandACL = status, .status
}

Example job definition /etc/bacula/Job/Studies2010-1.conf

#----------------------------------
Job {
  Name = Studies2010-1
  Type = Backup
  Client = nfs-prod-fd
  Schedule = MonthlyCycle
  Messages = Daemon
  FileSet = Studies2010-1
  Level = Full
  Pool = lto5-pool
  Priority = 12
  Max Run Time = 1555200 # default limit is 6 days, 518400sec. bumped 3x just in case
  Spool Data = yes
  Spool Attributes = yes

}
#----------------------------------

Example fileset, /etc/bacula/FileSet/Studies2010-1.conf

#-------------------------------------------
FileSet {
  Name = "Studies2010-1"
  Include {
    Options {
      signature = MD5
      compression=GZIP5
      noatime=yes
      aclsupport = yes
      wilddir = "/export/studies/201007*"
      wilddir = "/export/studies/201008*"
     	    }
    Options {
      RegexDir = ".*"
      exclude = yes
	    }
    File = "/export/studies"
          }
}

Example Schedule, /etc/bacula/Schedule/MonthlyCycle3.conf

Schedule {
  Name = MonthlyCycle3
  Run = Level=Full Pool=lto5-pool 3rd fri at 23:30
}

Tape library, storage definition:

Storage {
  Name = TapeLibrary
  Address = prod-tapelib.comain.com
  SDPort = 9103
  Password = "xxxxxx"
  Device = QuantumScalar-I40
  Media Type = LTO-5
  Autochanger = yes
  Maximum Concurrent Jobs = 4
}

Pool of tapes defined here:

Pool {
  Name = lto5-pool
  Pool Type = Backup
  Volume Retention = 6 months
  Recycle = yes
  AutoPrune = yes
  Recycle = yes
  Label Format = LTO5
  Storage = TapeLibrary
}

 

Relevant config files from Tape Library server

 

Note that I spool data before saving to the tape – this prevents tape “shoe shine” during Incremental/Differential backups.

 

  
Storage { 
  Name = TapeLibrary
  WorkingDirectory = "/var/spool/bacula"
  Pid Directory = "/var/run"
}
Autochanger {
  Name = QuantumScalar-I40
  Device = Drive0
  Device = Drive1
  Changer Device = /dev/changer
  Changer Command = "/usr/libexec/bacula/mtx-changer %c %o %S %a %d"
}
Device {
  Name = Drive0
  Drive Index = 0
  Media Type = LTO-5
  Archive Device = /dev/nst0
  AutomaticMount = yes
  AlwaysOpen = yes
  RemovableMedia = yes
  RandomAccess = no
  AutoChanger = yes
  Alert Command = "sh -c 'smartctl -H -l error %c'"  
  Maximum Changer Wait = 600
  Maximum Rewind Wait = 600
  Maximum Open Wait = 600
  Spool Directory = /var/spool/bacula/Spool
  Maximum Spool Size = 45G
  Maximum Concurrent Jobs = 2
}
Device {
  Name = Drive1
  Drive Index = 1
  Media Type = LTO-5
  Archive Device = /dev/nst1
  AutomaticMount = yes
  AlwaysOpen = yes
  RemovableMedia = yes
  RandomAccess = no
  AutoChanger = yes
  Alert Command = "sh -c 'smartctl -H -l error %c'"
  Maximum Changer Wait = 600
  Maximum Rewind Wait = 600
  Maximum Open Wait = 600
  Spool Directory = /var/spool/bacula/Spool
  Maximum Spool Size = 45G
  Maximum Concurrent Jobs = 2
     }
Messages {
  Name = Standard
  director = prod-backup-dir = all
}
Director {
  Name = prod-backup-dir
  Password = "xxxxxxxx"
}
Director {
  Name = prod-backup-mon
  Password = "xxxxxxxxxx"
  Monitor = yes
}

Thoughts

Implementing Bacula driven backup solution requires some time and effort – but what you get in the end is sophisticated, enterprise grade backup system, capable of backing up TBs of data in organised and efficient manner.

Used in conjunction with Monitoring system it offers fully automated backup solution, with minimal operator effort required. Routine tasks boil down to:

 


Jul 102015
 

Intro

 

So I had this crazy idea about fitting onboard computer to my 04′ Honda Accord Tourer (Exec trim with premium speaker system – non-navi version).
Been googling this and digesting available information, finally stumbled upon this excellent Engineering(DIY) project, blog and associated forum – and decided to give it a shot.

First sketch

 

Work in progress

 

Rear view camera fitted

 

Final effect

 

Shopping list

 

 

Diagram

 

Link to PDF version here

 

 

 Accord Radio Plug – source of power

One thing worth noting, in order to power things up we need access the radio plug. To access radio plug I had to remove the whole stereo/disc changer unit. Sounds tricky but this lovely chap has got it covered for you. I didn’t buy any stereo removal tools, simple wide steel spatula/scraper did the job. Once radio removed I could access the radio plug so carefully removed a bit of isolation from three wires and soldered my RPi2 /LCD power cables with fuses.

Was a bit scared of that part but it took less than an hour altogether. Jolly good.

Picture of actual plug, courtesy of http://accordklubpolska.pl/

 

 

What’s left on my to do list

  • Adding pyOBD based KODI plugin for engine real-time diagnostic, similar to the one from this page.
  • Rear seats, adding headrest mounted monitors for kids (via HDMI splitter).

Gallery

Full gallery with pictures is available here http://imgur.com/a/s0X3r

 Video presentation links

 

Some final thoughts

One note, if you would prefer to mount LCD a bit higher, say right above ventilation ducts, you might be interested in fitting this plastic panel instead of Double DIN fascia I used. Just an interesting alternative that was mentioned on one of the forums, alternative which I wasn’t aware of.

Apart of that, not much left to say as Andrei’s blog has most of the aspects covered.
But obviously if you have any Honda Accord specific question feel free to drop a comment here.

Many thanks to Andrei for publishing all necessary info and for keeping this awesome project alive.